DR-480 Power supply
480W Single Output Industrial DIN Rail Power Supply DR-480 series
Features:
Universal AC input/ full range
Built-in active PFC function
Protections: Short circuit/ Over load/ Over voltage/ Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
LED indicator for power on
100% full load burn-in test
Fixed switching frequency at 100KHz
2 years warranty
SPECIFICATIONS |
||
OUTPUT |
|
|
Model |
DR-480-24 |
DR-480-48 |
DC Voltage |
24V |
48V |
Rated Current |
20A |
10A |
Current Range |
0-20A |
0-10A |
Rated Power |
480W |
480W |
Ripple & Noise |
200mVp-p |
240mVp-p |
Voltage Adj. Range |
24-28V |
48-53V |
Voltage Tolerance |
±2% |
±2% |
Load regulation |
±1% |
±1% |
Setup, Rise Time |
800ms,40ms/230VAC 800ms,40ms/115VAC at full load |
|
Hold Up Time |
24ms/230VAC 24ms/115VAC at full load |
|
|
|
|
INPUT |
|
|
Voltage Range |
95~132VAC .180-264VAC 47~63Hz; 235~373VDC |
|
AC Current |
2.8A/115V 1.4A/230V |
|
Efficiency |
87% |
90% |
Inrush Current |
Cold start 45A/115VAC 60A/230VAC |
|
Leakage Current |
<3.5mA/240VAC |
|
|
|
|
PROTECTION |
|
|
Over Load |
105%~150% rated output power |
|
Protection type: Constant current limiting, recovers automatically after fault condition is removed |
||
Over Voltage |
27.8-30.6V |
54-57.8V |
Protection type: Shut down o/p voltage, re-power on to recover |
||
Over Temp. |
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down |
|
|
|
|
ENVIRONMENT |
|
|
Working Temp., Humidity |
-10℃~+60℃; 20%~90%RH non-condensing |
|
Storage Temp., Humidity |
-40℃~+85℃; 10%~95%RH |
|
Vibration |
10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
|
|
|
|
SAFETY |
|
|
Withstand Voltage |
I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC |
|
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC |
|
|
|
|
STANDARD |
|
|
Safety Standard |
Design refer to UL508,UL60950-1, TUV EN60950-1 |
|
EMC Standard |
EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2(EN50082-2), heavy industry level, criteria A |
|
|
|
|
OTHERS |
|
|
Dimension |
125.5*125.2*100mm(W*H*D) |
|
Weight |
1.2Kg |
|
Packing |
12pcs/15.5Kg/1.29CUFT |
|
|
|
|
NOTE |
|
|
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor. 3 .Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5 . Derating may be needed under low input voltages. Please check the derating curve for more details. |
110VAC/220VAC
50/60Hz