Home    SWITCH POWER SUPPLY    Din rail series power supply    DR-75 Din rail power supply

Product Details

DR-75 Din rail power supply

75W Single Output Industrial DIN Rail Power Supply Unit           DR-75 series

Features:
Universal AC input/ full range
Protections: Short circuit/ Over load/ Over voltage/ Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
LED indicator for power on
100% full load burn-in test
Fixed switching frequency at 50KHz
2 years warranty

SPECIFICATIONS

OUTPUT

 

Model

DR-75-12

DR-75-24

DR-75-48

DC Voltage

12V

24V

48V

Rated Current

6.3A

3.2A

1.6A

Current Range

0-6.3A

0-3.2A

0-1.6A

Rated Power

75.6W

76.8W

76.8W

Ripple & Noise

100mVp-p

150mVp-p

240mVp-p

Voltage Adj. Range

12-14V

24-28V

48-53V

Voltage Tolerance

±2%

±1%

±1%

Line regulation

±1%

±1%

±1%

Load regulation

±1%

±1%

±1%

Setup, Rise Time

1000ms,60ms/230VAC   1800ms,60ms/115VAC at full load

Hold Up Time

60ms/230VAC   12ms/115VAC at full load

 

 

INPUT

 

Voltage Range

85~264VAC   47~63 Hz; 120~370VDC

AC Current

1.6A/115V   0.96A/230V

Efficiency

76%

80%

81%

Inrush Current

Cold start 20A/115VAC   40A/230VAC

Leakage Current

<1mA/240VAC

 

 

PROTECTION

 

Over Load

105%~150% rated output power

Protection type: Constant current limiting, recovers automatically after fault condition is removed

Over Voltage

15-16.5V

29-34V

58-65V

Protection type: Shut down o/p voltage, re-power on to recover

Over Temp.

85℃±5℃ (TSW1) detect on heat sink of power transistor

Protection type: Shut down o/p voltage, recovers automatically after temperature goes down

 

 

ENVIRONMENT

 

Working Temp., Humidity

-10℃~+60℃; 20%~90% RH non-condensing

Storage Temp., Humidity

-20℃~+85℃; 10%~95%RH

Vibration

10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes

 

 

SAFETY

 

Withstand Voltage

I/P-O/P: 3KVAC   I/P-FG: 1.5KVAC   O/P-FG: 0.5KVAC

Isolation Resistance

I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC/25℃/70%RH

 

 

STANDARD

 

Safety Standard

Design refer to UL508,TUV EN60950-1

EMC Standard

EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,EN55024,EN61000-6-2, heavy industry level, criteria A

 

 

OTHERS

 

Dimension

55.5*125.2*100mm(L*W*H)

Weight

0.6Kg

Packing

20pcs/13Kg/1.29CUFT

 

 

NOTE

 

1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2.Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor.

3.Tolerance: includes set up tolerance, line regulation and load regulation.

4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

75W din rail switching power supply
110VAC/220VAC
50/60Hz

MESSAGE CONSULTATION

NAME: *

TELEPHONE: *

MAILBOX: *

QUESTION CONSULTATION *