Home    SWITCH POWER SUPPLY    S / LRS Single output power supply    LRS-200 Ultra thin power supply

Product Details

LRS-200 Ultra thin power supply

 

200W Single Output Switching Power Supply  LRS-200 series

Features:

AC input range selectable by switch

Withstand 300VAC surge input for 5 second

Protections: Short circuit / Overload / Over voltage/ Over temperature

Cooling by free air convection

LED indicator for power on

100% full load burn-in test

High operating temperature up to 70℃

High efficiency, long life and high reliability

2 years warranty

SPECIFICATION  
OUTPUT  
Model LRS-200-3.3 LRS-200-5 LRS-200-12 LRS-200-15 LRS-200-24 LRS-200-36 LRS-200-48
DC Voltage 3.3V 5V 12V 15V 24V 36V 48V
Rated Current 40A 40A 17A 14A 8.8A 5.9A 4.4A
Current Range 0~40A 0~40A 0~17A 0~14A 0~8.8A 0~5.9A 0~4.4A
Rated Power 132W 200W 204W 210W 211.2W 212.4W 211.2W
Ripple&Noise 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p
VoltageAdj. Range 2.97~3.6V 4.5 ~ 5.5V 10.2~ 13.8V 13.5~18V 21.6~28.8V 32.4~39.6V 43.2~52.8V
Voltage Tolerance ±3.0% ±3.0% ±1.5% ±1.0% ±1.0% ±1.0% ±1.0%
Line Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load Regulation ±2.5% ±2.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5%
Setup,Rise Time 1300ms, 50ms/230VAC   1300ms, 50ms/115VAC at full load
Hold Up Time 16ms/230VAC   12ms/115VAC at full load
   
INPUT  
Voltage Range 90 ~ 132VAC / 180 ~ 264VAC selected by switch   254 ~ 370VDC (switch on 230VAC)
Frequency Range 47 ~ 63Hz
Efficiency 83% 87% 87.50% 88% 89.50% 89.50% 90%
AC Current 4A/115VAC  2.2A/230VAC
Inrush Current Cold start 60A/115VAC   60A/230VAC
Leakage Current <2mA / 240VAC
   
PROTECTION  
Over Load 110 ~ 140% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
Over Voltage 3.8~4.45V 5.75~6.75V 13.8~16.2V 18~21V 28.8~33.6V 41.4~46.8V 55.2~64.8V
Protection type: Hiccup mode, recovers automatically after fault condition is removed
Over temperature Hiccup mode, recovers automatically after fault condition is removed
   
ENVIRONMENT  
Working Temp. -25 ~ +70℃ (Refer to “derating curve”)
Working Humidity 20 ~ 90% RH non-condensing
StorageTemp., Humidity -40 ~ +85℃, 10 ~ 95% RH
Temp. Coefficient ±0.03%/℃ (0 ~ 50℃)
Vibration 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
   
SAFETY  
Safety Standards UL60950-1 approved
Withstand Voltage I/P-O/P:3KVAC   I/P-FG:2KVAC  O/P-FG:0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH
   
OTHERS  
Dimension 215*115*30mm (L*W*H)
Weight 0.66Kg
Packing 15pcs/carton/10.9kg/0.78CUFT
   
NOTE  
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meetsEMC directives.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
200W Ultra thin switching power supply
SIngle output switching power supply
90 ~ 132VAC / 180 ~ 264VAC selected by switch
47 ~ 63Hz